Quick answer: This is a working glossary of the terms that appear on flame retardant datasheets, enquiries and specifications — grouped by where you meet them rather than alphabetically, with the common misreading noted for each. The five most frequently confused: RoHS is not halogen-free, LOI is not a certification, a rating is not a material property, PLC 0 is the best not the worst, and a Yellow Card covers compounds, not additives.

We wrote this because of enquiries like this one, which arrived more or less verbatim: “RoHS halogen-free V0 grade, high LOI, need UL certificate.” Four requirements, and three of them do not mean what the sender thought. RoHS permits most brominated flame retardants. V-0 is meaningless without a thickness. LOI is not a certificate and no standard in their market required it. Quoting that enquiry literally versus quoting what they actually needed differed by roughly a factor of three in price.

Ratings and Classes

What a material is graded as. Note that every one of these belongs to a specific test on a specific specimen — they are not interchangeable, as set out in the standards comparison.

TermWhat It MeansWhere People Get It Wrong
V-0 / V-1 / V-2UL94 vertical burn classes. V-0: ≤10 s afterflame per application, ≤50 s total over ten applications, no drips igniting cotton⚠️ V-1 and V-2 have identical time limits — only dripping separates them. And no rating is valid without a stated thickness
HBHorizontal burning; ≤40 mm/min at 3–13 mm, ≤75 mm/min below 3 mm⚠️ Many unmodified plastics already pass. If your drawing says HB you may need no flame retardant at all
5VA / 5VBLarger-flame enclosure ratings. 5VA is the highest UL94 classThe only difference: 5VB allows a burn-through hole, 5VA does not
VTM-0 / -1 / -2The thin-material version, specimen wrapped on a 12.7 mm mandrelA film cannot be “V-0” — it is VTM-0. Treat a V-0 film claim as a question
LOILimiting oxygen index: minimum O₂% sustaining combustion. Air is 20.9%⚠️ A development metric, not a certification — except in rail, GB supply chains and some cable tenders where it is contractual
FSI / SDIFlame Spread Index / Smoke Developed Index from ASTM E84. Class A = FSI 0–25 and SDI ≤450Both thresholds are mandatory. Halogenated systems often pass FSI and fail on smoke
Euroclass (EN 13501-1)A1, A2, B, C, D, E, F for construction products, plus s1–s3 smoke and d0–d2 droplets“Class B” alone is not a specification. It must read like B-s1,d0
GB 8624China’s construction product classes: A, B1, B2, B3⚠️ B1 is not Euroclass B. Four classes vs seven, no official mapping
HL1 / HL2 / HL3EN 45545-2 rail hazard levels. HL3 requires LOI > 32Rail clauses get copied onto non-rail parts, which multiplies cost for nothing
CPR Euroclass (cable)Aca to Fca for cables in EU construction worksA separate scale from the EN 13501-1 letters despite looking similar
CMP / CMR / OFNP / OFNRNEC cable listings (plenum / riser), earned via NFPA 262 and UL 1666⚠️ Plenum-rated does not mean halogen-free — most plenum cable is fluoropolymer

Electrical Properties

The requirements a burn rating says nothing about. For electronics these usually decide the formulation — see flame retardant for electronics.

TermWhat It MeansWhere People Get It Wrong
CTIComparative tracking index (IEC 60112): voltage a surface resists before forming a conductive carbon pathNot a fire test at all. Brominated + antimony systems typically track worse
PLCPerformance level category, 0–5, from the CTI result⚠️ PLC 0 is the best (≥600 V), not the worst. Lower number = stronger, same as on a Yellow Card
GWITGlow wire ignition temperature (IEC 60695-2-13). ≥775 °C clears unrestricted use in current-carrying appliance parts⚠️ V-0 does not predict it. UL94 removes the flame; glow wire keeps the heat on
GWFI / GWTGlow wire flammability index (>850 °C typical) / glow wire test on the finished part (750 °C, ≤2 s)GWT is tested on your part, not on a plaque — a different obligation
RTIRelative thermal index: long-term temperature capability, separate electrical and mechanical valuesIgnored at design stage, then decides whether the part survives ten years
HWI / HAIHot wire ignition / high-current arc ignition (UL 746A)Set by the electrical function of the part, not by the resin family

Chemistry and Abbreviations

The acronyms on a technical datasheet. Each links to the detail where we have it.

AbbreviationFull NameTypical Use and Caveat
ATH / MDHAluminium trihydroxide / magnesium dihydroxideMineral, works by heat absorption. Needs 55–65% loading. ATH decomposes ~200 °C, MDH ~330 °C — the reason MDH goes into PP and PA
APPAmmonium polyphosphateAcid source in intumescent systems. Calcium carbonate in the same formulation will neutralise it
MCAMelamine cyanurate⚠️ Excellent in unfilled nylon, close to useless once glass fibre stops the dripping it relies on
MPPMelamine polyphosphateCommon partner to phosphinate in glass-filled polyamide
DEPAL / OPAluminium diethylphosphinateMainstream halogen-free route for reinforced PA and PBT; supports high CTI
DOPO9,10-dihydro-9-oxa-10-phosphaphenanthrene-10-oxideReactive phosphorus, bonded into epoxy. The halogen-free laminate workhorse
BDP / RDP / TPPBisphenol-A / resorcinol / triphenyl phosphateLiquid phosphate esters for PC and PC/ABS. TPP is the most volatile, BDP the most hydrolysis-resistant
EGExpandable graphiteExpands into an insulating worm. Particle size dictates whether it survives your process
KSSPotassium diphenyl sulfone sulfonateUsed at very low dose in transparent PC where clarity must survive
DBDPEDecabromodiphenyl ethaneThe mainstream PBDE replacement. RoHS compliant, but inside the scope ECHA is preparing a restriction on
TBBPATetrabromobisphenol AHighest-volume BFR worldwide. Mostly reactive in laminate, which changes its regulatory position
PBDE / HBCDPolybrominated diphenyl ethers / hexabromocyclododecane⚠️ Banned as POPs. Still turn up in recycled feedstock
Sb₂O₃Antimony trioxideSynergist for halogen systems — not a flame retardant alone. IARC 2B classified
Zinc borate / stannateAntimony replacements and char promotersBuy char quality and smoke suppression, not much LOI
PTFE (anti-drip)Fibrillating polytetrafluoroethylene⚠️ Under 1% does nothing for LOI and is often what wins V-0 — it fixes dripping, not flammability
IntumescentAcid source + carbon source + blowing agent that swell into a foamed charSensitive to anything alkaline in the formulation
Gas phase / condensed phaseInterrupting flame chemistry vs building a protective charExplains why gas-phase systems pass UL94 but not glow wire
Candlewick effectGlass fibres wicking molten polymer to the flameWhy reinforced grades need more flame retardant, not less

Standard Numbers You Will Meet

Worth separating these out, because a recurring confusion is treating a test method as if it were a requirement. A method tells you how to measure; the required value comes from a product standard or a customer specification.

NumberWhat It IsMethod or Requirement?
UL 94 / IEC 60695-11-10 / GB/T 2408Horizontal and vertical burning of plastics — the same test in three numbering systemsMethod
ASTM D2863 / ISO 4589-2 / GB/T 2406Limiting oxygen indexMethod
ASTM E84Steiner tunnel, 25-foot flame spreadMethod — Class A comes from the building code, not from E84
EN 13501-1 / GB 8624Reaction-to-fire classification for construction productsRequirement (classification systems, not equivalent to each other)
IEC 60112Comparative tracking indexMethod (UL 746A assigns the PLC)
IEC 60695-2-11 / -2-12 / -2-13GWT (finished part) / GWFI / GWITMethod — IEC 60335-1 sets the values for appliances
IEC 60332-1 / -3Cable flame propagation, single wire / bunched in a trayMethod
IEC 61034 / IEC 60754 / IEC 60331Smoke density (3 m cube) / acid gas / circuit integrity in fireMethod — the three clauses beyond propagation
NFPA 262 / UL 1666Plenum and riser cable fire tests behind NEC listingsMethod
FMVSS 302 / ISO 3795Vehicle interior horizontal burn, ≤102 mm/minRequirement (and a low one)
EN 45545-2Rail vehicle fire behaviour, hazard levels HL1–HL3Requirement
IEC 62368-1 / IEC 60335-1Safety standards for AV/IT equipment and household appliancesRequirement — they invoke the methods above

Regulatory Terms

TermWhat It MeansWhere People Get It Wrong
RoHSEU restriction of ten substance groups in electrical equipment⚠️ Only two are brominated (PBB, PBDE). DBDPE, TBBPA and brominated PS are all RoHS compliant. RoHS ≠ halogen-free
IEC 61249-2-21The actual halogen-free definition: Br ≤900, Cl ≤900, total halogen ≤1500 ppmThis is the number to specify when you mean halogen-free. Not a fire test
REACH / SVHCEU chemicals regulation / substances of very high concern candidate listRegistration duty falls on the EU importer, not the Chinese supplier
POPs / UTCPersistent organic pollutants / unintentional trace contaminant limit⚠️ PBDE UTC is now 10 mg/kg general, but 350 mg/kg for recycled content, falling to 200 in Dec 2027
Yellow CardUL’s listing for a recognised plastic material, stating grades, colours and thicknesses evaluated⚠️ Issued for compounds, not additives. No additive supplier can give you one
Recognized vs ListedComponent recognition vs a finished-product listingBuying recognised material does not make your device listed

Commercial and Processing Terms

TermWhat It MeansPractical Note
phrParts per hundred resin⚠️ Not the same as weight percent. 20 phr ≈ 16.7 wt% — a real source of dosing errors
Let-down ratioHow much masterbatch you add per unit of base resinCompare masterbatches on active content, never on price per kilo
Additive / masterbatch / compoundPowder, pellet concentrate, ready-to-run materialAbove roughly 40–50% loading, compound usually beats dosing on your own line
Carrier resinThe polymer holding the additive in a masterbatchIt is up to a third of what you buy, and it ends up in your part
Blooming / plate-out / migrationAdditive surfacing on the part / depositing on tooling / leaving the matrix over timeAll three point at the same thing: something is mobile in your formulation
PCRPost-consumer recycled materialWEEE-origin PCR carries legacy POPs risk; screen before formulating
TDS / SDS / COATechnical data sheet / safety data sheet / certificate of analysisOnly the COA is lot-specific. The other two describe the product in general
LSZH / LS0H / LSFLow smoke zero halogen — a cable compound class, usually mineral-filled polyolefin⚠️ A material category, not a rating. “LSZH” on its own does not tell you which IEC clauses it passes
MFI / MFRMelt flow index / rate — how easily the melt flowsHigh filler loading drops it hard; thin-wall parts need flow and high loading at once, which is the core tension
Char yieldResidue left after burning — the protective layer condensed-phase systems rely onWhat glow wire and large-scale tests reward, and what gas-phase chemistry does not build
Smoke densityLight obscuration by smoke (IEC 61034 for cable, SDI within ASTM E84)The clause that most often fails an otherwise passing halogenated formulation
MOQMinimum order quantityAsk separately for trial quantity — sampling and production MOQ are different conversations

The Five That Cost the Most

If you take only one thing from this page, take these — they are the misreadings that turn into wrong quotes, failed certifications and wasted development cycles.

  1. RoHS compliant is not halogen-free. Different requirements, and a RoHS certificate tells you nothing about halogen content.
  2. A rating is not a material property. V-0 belongs to a material at a thickness in a colour. “Our material is V-0” is an incomplete sentence.
  3. LOI is not a certification unless a specification names it — and in rail and parts of the Chinese market, it does.
  4. PLC 0 is the best CTI category, not the worst. Low numbers mean strong performance here.
  5. A Yellow Card covers compounds, not additives. Asking an additive supplier for one has no valid answer.

Get an enquiry right on those five and most of the back-and-forth disappears. Send us the clause rather than the paraphrase, with the thickness and the colour, and we can usually answer in one reply instead of four.

—— Rectivas Materials 团队 技术工程师老陈